Deveco Tri 110

 

Deveco Tri 110 can be used at 3 to 5% as a single-dip low-corrosion trivalent liquid chromate that produces a clear blue bright chromate conversion coating on electroplated zinc and delivers up to 48 hrs protection to white corrosion in salt fog testing when operated per recommended conditions.  Note: It does not accept dyes well, however.

 

Deveco Tri 110 can also be used at higher concentrations, i.e. 9 to 11%, to make a high-corrosion trivalent  clear chromate on zinc plate that exceeds 144 hrs protection to white corrosion in neutral salt fog testing.

 

Deveco Tri 110 can be used on barrel and rack zinc plating lines.  It is equally effective on all electroplated zinc ranging from alkaline non-cyanide to acid chloride processes. It also works well on Zn-Ni-alloys 

 

Trivalent chromates typically provide better corrosion resistance after some zinc has built in the bath.  Typically, zinc builds in the chromate from the zinc-plated parts.  To provide some zinc in a new make-up, add Deveco Tri-Kote MU Addtv

 

Each 1% addition of Tri-Kote MU Addtv into a new chromate increases the zinc concentration 1,000 PPM.  3,000 PPM Zinc is typically the level where corrosion protection of a new make-up improves toward optimum.  Over 30,000 PPM zinc in the chromate reduces the corrosion protection of the chromate film.  It’s recommended a new bath be made when zinc exceeds 20,000 PPM. Keeping 10-15 % of the old chromate to seed the new chromate bath will eliminate the need to add Tri-Kote MU Addtv to build the zinc level.

 

MAKE-UP AND CONTROL:

Blue-bright, Low-corrosion

Recommended

Range

Deveco Tri 110

4% by volume

3 to 5 % by volume

Deveco Tri-Kote MU Addtv

1.5% by volume

1 to 2 % by volume

Temperature

80 oF

70 to 100 oF

Time

45 seconds

30 to 60 seconds

PH

2.0

1.8 to 2.5

 

High-corrosion

Recommended

Range

Deveco Tri 110

10% by volume

9 to 11 % by volume

Deveco Tri-Kote MU Addtv

3% by volume

2 to 4 % by volume

Temperature

80 oF

70 to 100 oF

Time

45 seconds

30 to 60 seconds

PH

2.0

1.8 to 2.5

 

1.       Make-up the Deveco Tri 110 solution and raise the pH into operating range using 50% Caustic Soda.

 

2.       Use Nitric Acid to lower pH (if necessary) during make-up. 

3.       Once pH is in range, add Deveco Tri-Kote MU Addtv.

4.       During operation, maintain the recommended pH range with additions of Deveco Tri 110.


 

 

 

Deveco Tri 110

Page 2 of 2

 

ANALYSIS:

 

The standard chrome titration method doesn’t produce a good end-point on a Tri 110 solution, so we recommend checking chrome on the AA to determine Tri 110 concentration.

 

  1. Deveco Tri 110 can be analyzed by testing for PPM Chrome on the A.A. 

  2. Each 1% Deveco Tri 110 represents 75 PPM chrome.

(PPM Chrome) / 75 = % Deveco Tri 110 solution.

 

CAUTION:

In case of contact, flush contaminated area with a large amount of water.  When handling this product, protective clothing, i.e. rubber apron, gloves, boots, and goggles should be worn.

 

Read Material Safety Sheet before using this product.

 

EQUIPMENT:

 

Deveco Tri 110 solutions require polyethylene, stainless steel, or koroseal lined tanks.

 

DISCLAIMER:

The information presented herein, while not guaranteed, is to the best of our knowledge true and accurate.  No warranty or guarantee expressed or implied is made regarding the performance of any products, since the manner of use is beyond our control.  No suggestion for product use or anything contained herein shall be construed as recommendation for its use in infringement of any existing patent and we assume no responsibility or liability for operations which do infringe any such patents.  The above includes confidential and proprietary information of Deveco Corporation and is furnished to you for your use solely on products or processes supplied by us to you.

 

Product Data Sheets/KR139                                   Effective Date: 1-3-07                                           Supersedes: 12-27-06