Deveco 404-SL is a liquid dichromate used to make an inexpensive chromate dip for producing iridescent and golden chromate coatings on zinc plate, zinc-nickel plate, zinc die-castings and cadmium plate. The chromate conversion coating produced has excellent corrosion resistance and serves as a very good base for paint.
MAKE-UP AND CONTROL: Zinc, Zinc-Nickel and Cadmium plate:
1 - 1.5 % by volume Deveco 404-SL.
For Zinc and Cadmium, the solution is operated at 65 - 90°F.
For Zinc-Nickel, the solution is operated at 90 – 110 °F.
Immersion time varies from 15 - 60 seconds.
pH 1.5 to 2.0
Zinc die cast:
1 ½ - 2 % by volume Deveco 404-SL.
The solution is operated at a temperature of 65 – 90°F.
Immersion time varies from 15 – 60 seconds.
pH 1.5 to 2.0
To achieve the maximum salt spray performance and corrosion protection, parts finished with 404-SL should by dried at 120 – 150°F.
ANALYSIS PROCEDURE:
pH Analyze using pH meter.
Ø Recommended Range: (1.5 to 2.0)
% Deveco 404SL
Ø Recommended Range: (1 to 2%)
Pipette 10 mls of sample into a 250 ml Erlenmeyer flask.
Add about 50 mls of DI water.
Add about 2 g of NH4FHF (Ammonium Bifluoride).
Add about 30 mls of 50% HCl (Hydrochloric Acid) and about 10 mls of 10% KI (Potassium Iodide). Solution will become dark.
Begin titrating with 0.1 N Na2S2O3 (Sodium Thiosulfate) and continue until solution begins to lighten.
Add about 5 mls of starch indicator solution. Solution will again darken.
Resume titrating until solution becomes clear (all iodine color is gone).
Calculate % Deveco 404SL concentration:
% Deveco 404SL = 0.15 x (mls 0.1N Na2S2O3)
Zinc Analyze by Atomic Absorption Spectrometer
Ø Recommended Range: (Maintain below 20,000 PPM by decanting or dumping)
Ø Above 30,000 PPM, zinc will inhibit the chromating reaction and reduce the corrosion protection of the chromate film.
CAUTION:
This product contains chromates and is acid in nature. Contact of salts or solution with skin or eyes should be avoided. In case of contact, flush contaminated area with a large amount of water. When handling this product, protective clothing, i.e. rubber apron, gloves, boots, and goggles should be worn.
EQUIPMENT:
Deveco 404-SL solutions require polyethylene, stainless steel, or koroseal lined tanks.
Read Material Safety Sheet before using this product.
DISCLAIMER:
The information presented herein, while not guaranteed, is to the best of our knowledge true and accurate. No warranty or guarantee expressed or implied is made regarding the performance of any products, since the manner of use is beyond our control. No suggestion for product use or anything contained herein, shall be construed as a recommendation for its use in infringement of any existing patent and we assume no responsibility or liability for operations which do infringe any such patents. The above includes confidential and proprietary information of Deveco Corporation and is furnished to you for your use solely on products or processes supplied by us to you.
Product Data Sheet/KR006 Effective Date: 08/06/01